金年会·(中国)官方网站-在线入口

Power Quality Analyzer and Homonics Control
Your Current Location: Home > Products > Power Quality Analyzer and Homonics Control
  • ARZ®-3W

    Product Profile

    ARZ®-3W power quality analyzer is an integrated monitoring, analyzing and controlling device that offers electrical parameter metering, harmonics metering and analysis, waveform sampling, measurement of Voltage swell, dip, interrupt, Voltage unbalanced ratio, demand, fault record, event record, data record. ARZ®-3W can monitor and detect if the power quality fulfills IEC and EN standard.

    ARZ®-3W fulfils all the important requirements of IEC 61000-4-30 Class A standard.

    ARZ®-3W can work with our power quality monitoring and management software to provide energy management solutions for enterprises. With its strong networking capability, ARZ®-3W can display and record all the data records on the interactive trend chart. A data report can be formed periodically. The report can be used for fault analysis, statistics, real time monitoring purpose.

    Application

    >Power quality detection and management

    >Disturbance analysis, faults analysis, device pre-maintenance

    >Long term record and analysis

    >Power loads analysis

    >Energy consumption evaluation and analysis

    >Utilizing GPS synchronization to analyze the relevance between events in different locations

    >Applied scope: Single phase and 3phase electrical power system

     

    Main functions

    Measured scope

    1P2W3P3W3P4W3P5W  programmable

    Basic parameters measurement:

    Voltage, Current (including, negative, zero sequence Current), frequency, power factor, active power, reactive power, apparent power, active energy, reactive energy, energy demand, Current/Voltage unbalance ratio, energy demand.

    Harmonics monitoring indicator

    Harmonics (2nd to 127th), including total Voltage/Current harmonic distortion ratio, each harmonic ratio, magnitude, phase angle, active power, reactive power, etc.

    Inter-harmonics(1.5 to 126.5)

    Voltage flicker quickly (Pst), flicker slowly (Plt), swell, dip, interrupt and transient change (optional).

    Surging Current (optional, only valid when matching with power clamp sensor outside)

    Oscillograph, waveshape faults record

    Real time display Voltage and Current waveform. Form the Voltage waveform and faults record on the occasion of harmonic component overlimit, harmonic distortion overlimit, R.M.S Voltage overlimit, short circuit fault etc.

    Parameter record, event alarm

    The built-in memory can record all the data that is needed, with the capacity of 32GB.

    Power quality reliability detection

    Display power quality detection result

     

    Multi communication protocol

    Modbus-RTUTCP/IP, etc.

    Help/guide function

    User-friendly

    Display and operate function

    TFT true color LCD: resolution 640×48065535 colors; touch screen and key dual operation mode; wave display support scaling  operation.

    Other functions

    Online statistics; GPS synchronization.

    Measurement Accuracy

    U, I rms value:  0.05%

    U, I peak value, peak factor:  2%

    Flicker:  5%

    Voltage unbalanced and Current unbalanced:  0.2%

    Frequency: ±0.002Hz

    Power factor:  ±0.002

    Power:  0.05%

    Energy:  Active energy 0.05% IEC60687:1992(GB/T17883-1999)

            Reactive energy 0.05% IEC61268(1995) (GB/T17882-1999)

    Harmonics:   IEC61000-4-30 class A

    Inter-harmonics:   IEC61000-4-30 class A

    Interface

      

     

     

    Technical Specification

    1.       Input

    a.AC Current input

    Input method: Internal Current transformers: 4 channels

    Nominal input: 1A~5A rms

    Measure scope: 0.001A~7A rms

    With power clamp sensor outside: 1A~3000A

    Power consumption:0.5VA/phase

    Overload capacity: 10A continuously, 100A /1s non continuously

     

    b.AC Voltage input

    Input method: Internal resistance partial voltage: 4 channels

    Nominal input: 100V~750V rms

    Measure scope: 0.2V~900V rms

    Power consumption:0.1VA/phase

    Overload capacity:1000V rms continuously, 6000V/1s non continuously

    Frequency scope:50/60 Hz±15%

     

    c.Remote signal input

    34 channels remote signal input 24VDC

    GPS synchronized port: TTL (B code), 485(B code)

     

    2.       Output

    a. 16 relay alarm outputs, 10A/250VAC/30VDC

    b. Communication port: RS-485 (baud rate: 2400, 4800, 9600, 19200bps)

    c. Dual Ethernet: (dual 10M/100M Ethernet)

    d. USB

     

    3.       Environment

    Operation temperature:-20~+60

    Storage temperature:-40~+85

    Operation humidity: 5%~95%RH

    Sea height: up to 2000m.

    Pollution class: Class II

    Material of housing: Duralumin

    Protection class: IP51

     

    4.       Other parameters

    Auxiliary power supply: 85-265VAC/DC

    Sampling frequency: 20.48k (50Hz)

    Sampling resolution: 19 digits

    Event detection time:48μs

    Data storage capacity: 32GB

    Temp. drifting factor:<10PPM/.

    Withstand Voltage (input against output):3000V/1min (2mA)

    Power comsumption: 20VA

     

    5.       EMC and safety test

    EN61326-1 EN61000-4-2/3/4/5/12

    IEC/EN61010-2001

  • ARZ-3L

    Product Profile

    ARZ®-3L power quality analyzer is an integrated monitoring, analyzing and controlling device that offers electrical parameter metering, harmonics metering and analysis, waveform sampling, measurement of Voltage swell, dip, interrupt, Voltage unbalanced ratio, demand, fault record, event record, data record. ARZ®-3L can monitor and detect if the power quality fulfills IEC and EN standard.

    ARZ®-3L fulfils all the important requirements of IEC 61000-4-30 Class A standard.

    ARZ®-3L can work with our power quality monitoring and management software to provide energy management solutions for enterprises. With its strong networking capability, ARZ®-3L can display and record all the data records on the interactive trend chart. A data report can be formed periodically. The report can be used for fault analysis, statistics, and real time monitoring purpose.

    Application

    >Power quality detection and management

    >Disturbance analysis, faults analysis, device pre-maintenance

    >Long term record and analysis

    >Power loads analysis

    >Energy consumption evaluation and analysis

    >Utilizing GPS synchronization to analyze the relevance between events in different locations

    >Applied scope: Single phase and 3phase electrical power system

     

    Main functions

    Measured scope

    1P2W3P3W3P4W3P5W  programmable

    Basic parameters measurement:

    Voltage, Current (including, negative, zero sequence Current), frequency, power factor, active power, reactive power, apparent power, active energy, reactive energy, energy demand, Current/Voltage unbalance ratio, energy demand.

    Harmonics monitoring indicator

    Harmonics (2nd to 127th), including total Voltage/Current harmonic distortion ratio, each harmonic ratio, magnitude, phase angle, active power, reactive power, etc.

    Inter-harmonics(1.5 to 126.5)

    Voltage flicker quickly (Pst), flicker slowly (Plt), swell, dip, interrupt and transient change (optional).

    Surging Current (optional, only valid when matching with power clamp sensor outside)

    Oscillograph, waveshape faults record

    Real time display Voltage and Current waveform. Form the Voltage waveform and faults record on the occasion of harmonic component overlimit, harmonic distortion overlimit, R.M.S Voltage overlimit, short circuit fault etc.

    Parameter record, event alarm

    The built-in memory can record all the data that is needed, with the capacity of 32GB.

    Power quality reliability detection

    Display power quality detection result.

    Multi communication protocol

    Modbus-RTUTCP/IP, etc.

    Help/guide function

    User-friendly

    Display and operate function

    TFT true color LCD: resolution 640×48065535 colors; touch screen and key dual operation mode; wave display support scaling  operation.

    Other functions

    Online statistics; GPS synchronization; Network synchronization

    Event alarming

    Event triggered alarming function through e-mail and SMS.

    Measurement Accuracy

    U, I rms value:  0.1%

    U, I peak value, peak factor:  2%

    Flicker:  5%

    Voltage unbalanced and Current unbalanced:  0.2%

    Frequency: ±0.002Hz

    Power factor:  ±0.002

    Power:  0.1%

    Energy:  Active energy 0.05% IEC60687:1992 (GB/T17883-1999)

            Reactive energy 0.05% IEC61268 (1995) (GB/T17882-1999)

    Harmonics:   IEC61000-4-30 class A

    Inter-harmonics:   IEC61000-4-30 class A

    Interface

     

    Technical Specification

    1、Input

    a、AC Current input

    Input method: Internal Current transformers: 4 channels

    Nominal input: 1A~5A rms

    Measure scope: 0.001A~7A rms

    With power clamp sensor outside: 1A~3000A

    Power consumption:0.5VA/phase

    Overload capacity: 10A continuously, 100A /1s non continuously

     

    b、AC Voltage input

    Input method: Internal resistance partial voltage: 4 channels

    Nominal input: 100V~750V rms

    Measure scope: 0.2V~900V rms

    Power consumption:0.1VA/phase

    Overload capacity:1000V rms continuously, 6000V/1s non continuously

    Frequency scope:50/60 Hz±15%

     

    c、Remote signal input

    6 channels remote signal input 24VDC

    GPS synchronized port: TTL (B code), 485(B code)

     

    2、Output

    a、4 relay alarm outputs, 10A/250VAC/30VDC

    b、Communication port: RS-485 (baud rate: 2400, 4800, 9600, 19200bps)

    c、1 channel Ethernet: (10M/100M Ethernet)

    d、USB

     

    3、Environment

    Operation temperature:-20~+60

    Storage temperature:-40~+85

    Operation humidity: 5%~95%RH

    Sea height: up to 2000m.

    Pollution class: Class II

    Material of housing: Duralumin

    Protection class: IP51

     

    4、Other parameters

    Auxiliary power supply: 85-265VAC/DC

    Sampling frequency: 20.48k (50Hz)

    Sampling resolution: 19 digits

    Event detection time:48μs

    Data storage capacity: 32GB

    Temp. drifting factor:<10PPM/.

    Withstand Voltage (input against output):3000V/1min (2mA)

    Power comsumption: 15VA

     

    5、EMC and safety test

    EN61326-1 EN61000-4-2/3/4/5/12

    IEC/EN61010-2001